Brand: Ashland | Category: Medical Equipment

A self-developing radiochromic film for machine quality assurance ahead of patient treatment planning, covering IMRT, VMAT, brachytherapy, Star Shot, Picket Fence and flatness and symmetry tests. Ashland states a dose range of 0.2 Gy to 10 Gy and an energy range from 100 keV into the MV range.
| Parameter | Value |
|---|---|
| Manufacturer-listed dose range | 0.2–10 Gy |
| Manufacturer-listed energy range | 100 keV into the megavoltage range |
| EBT3-810 | 8 × 10 in; 25 sheets; product code 828204 |
| EBT3-1417 | 12.8 × 17 in; 10 sheets; product code 828206 |
| EBT3P | 8 × 10 in; 25 sheets; product code 841975; pre-punched for Quick Phantom |
Ashland EBT3 product page. Select the exact sheet format and lot; dose measurement requires the appropriate calibration, scanner and validated analysis workflow. EBT3P is the pre-punched option. Checked 2026-09-29.
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Ashland equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
An extended dose radiochromic film for patient quality assurance in stereotactic radiosurgery, small field dosimetry and hypofractionated treatments. Ashland states a dose range of 0.4 Gy to 40 Gy and an energy range from 100 keV into the MV range.
Waiting for scheduled maintenance to reveal a failing blood irradiator can be too late, so Ashland offers dose-Map as a routine three step check that anyone able to operate a blood irradiator can carry out. The cassette arrives from Ashland, goes into the canister for a normal cycle, and is posted back for analysis. Ashland then reads the film inside and issues a report carrying a dose distribution chart and a colour-coded dose contour plot showing how absorbed dose is distributed through the canister.
A radiochromic film for routine radiotherapy machine quality assurance, including light field and radiation field alignment tests, Star Shot, Picket Fence, flatness and symmetry tests, and position verification for high dose rate brachytherapy. Ashland states a dose range of 0.2 Gy to 10 Gy and an energy range from 100 keV into the MV range.