Brand: EDIBON | Category: Scientific & Laboratory Equipment

FME12 is a bench module with two centrifugal pumps that can be run singly, in series or in parallel. Head and flow are measured for each arrangement so students can build the combined characteristic curves and see how the duty point changes.
| Parameter | Value |
|---|---|
| Centrifugal pump power | 0.37 kW |
| Published pump duty | 30–80 l/min at 20.1–12.8 m head |
| Pump-inlet pressure gauge | −1 to 3 bar |
| Discharge pressure gauges | 0–4 bar |
| Unit dimensions | 500 x 400 x 400 mm approx. |
| Unit weight | 20 kg approx. |
Selected data from the model-specific panel on page 22 of the manufacturer LIFLUBA brochure. Unit dimensions and weights are approximate. The hydraulic bench/feed system and other required elements may be supplied separately; confirm the current model, accessories and complete quotation scope. Checked 2026-09-29.
Manufacturer reference document (opens in a new tab)
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about EDIBON equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
FME13 is a bench module for testing a single centrifugal pump. Head, flow, speed and power are measured so the characteristic curves and the efficiency of the pump can be plotted and the affinity laws checked.
Built around a small-scale Pelton turbine, the "HT-P" Pelton Turbine Model has a valve that allows the flow to be regulated. A PELTON runner with 16 buckets is included in the turbine, clearly visible through its transparent casing.
FME38 demonstrates the hydraulic ram, a pump driven by the water hammer effect that needs no external power source. Supply head, delivery head and flow are measured so the efficiency of the ram can be calculated.