Brand: GEMMY Industrial | Category: Medical Equipment

A bench top steam steriliser with a 230 mm diameter by 390 mm deep chamber in 304 stainless steel, approximately 16 litres, in an overall cabinet of 501 x 406 x 537 mm. Design temperature is 140 degrees C and the published working range for unwrapped, wrapped and liquid loads is 115 to 134 degrees C at 0.9 to 2.1 kg/cm2. GEMMY states the autoclave is manufactured in conformity with directive 93/42/EEC. Safety fittings are a safety valve, an emergency exhaust valve, a release valve, a door safety holder and a pressure control switch.
| Parameter | Value |
|---|---|
| Dimensions | 500 × 540 × 406 mm |
| Chamber size | 230 × 410 mm |
| Nominal capacity | 16 L |
| Heater | 1,400 W |
| Listed temperature | 118–134°C |
| Power variants | 115 or 230 V |
GEMMY 2026 catalogue, page 25, exact model column. Confirm voltage, cycle validation and load suitability before procurement; a temperature rating alone does not define a validated sterilization cycle. Checked 2026-09-29.
Manufacturer reference document (opens in a new tab)
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about GEMMY Industrial equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
A Class B table top steriliser with a 40 litre chamber measuring 300 mm diameter by 570 mm deep, running at 121 or 135 degrees C with an automatic fill water system and a vacuum assisted drying stage selectable at 0, 15, 30, 35 or 40 minutes. Programmes cover wrapped and unwrapped loads, dry and undried, liquids, a PRION programme, Bowie-Dick and a pump test, with temperature shown digitally, pressure on a pressure and vacuum gauge and programme status on LED. It draws 3000 W at 14 A, split between a 2300 W heater, a 600 W dry heater and a 100 W vacuum pump, from a 230 V 50/60 Hz supply. Safety cover includes a 2.5 kg/cm2 pressure safety valve, independent over temperature protection, two 30 A no fuse breakers, an over pressure switch, a door lock micro-switch, water level sensors in both the tank and the chamber, and a silicone bellows pressure door lock.
A portable steam steriliser with a 230 mm diameter by 410 mm deep chamber in 304 stainless steel, giving roughly 16 litres in an overall footprint of 335 x 430 x 600 mm. Design temperature is 140 degrees C, with sterilising pressure of 1.4 kg/cm2 at approximately 122 degrees C, and the published cycle table quotes 122 degrees C at 1.12 kg/cm2 for unwrapped, wrapped and liquid loads. Several internal programmes are preset for selection, and GEMMY lists the machine for dental clinics, hospitals and laboratories handling wrapped, unwrapped, liquid and utensil loads. Safety devices are an overheat and low water cut-off switch, a safety valve and a release valve.
A vertical steam steriliser whose cycle runs automatically through conditioning and sterilising phases, with sterilising temperature adjustable from 121 to 132 degrees C and sterilising time from 0 to 60 minutes. The timer only starts once the preset temperature has been reached, and a buzzer announces completion and cuts the heating supply. The cylindrical chamber is SUS 316 stainless steel with a polished surface, thermally insulated with fibreglass and clad in stainless sheet, fitted with a steam trap to discharge condensate and a HEPA air filter to keep contaminated air out. The door is operated manually by a rotating handle with a foot pedal to lift it, sealed by a silicone rubber gasket, and safety cover includes a door interlock, a safety valve, over temperature cut-off, circuit breaker and fuse protection, and a manual emergency exhaust for power outages.