Brand: GEMMY Industrial | Category: Medical Equipment

A portable steam steriliser with a 230 mm diameter by 410 mm deep chamber in 304 stainless steel, giving roughly 16 litres in an overall footprint of 335 x 430 x 600 mm. Design temperature is 140 degrees C, with sterilising pressure of 1.4 kg/cm2 at approximately 122 degrees C, and the published cycle table quotes 122 degrees C at 1.12 kg/cm2 for unwrapped, wrapped and liquid loads. Several internal programmes are preset for selection, and GEMMY lists the machine for dental clinics, hospitals and laboratories handling wrapped, unwrapped, liquid and utensil loads. Safety devices are an overheat and low water cut-off switch, a safety valve and a release valve.
Plan your specification
Describe what you need to process and where the unit will be used. Have the responsible laboratory or clinical team confirm that the proposed model and documented operating scope match the intended application before purchase.
Review autoclave, oven and incubator performance considerations
| Parameter | Value |
|---|---|
| Dimensions | 335 × 510 × 430 mm |
| Chamber size | 230 × 410 mm |
| Nominal capacity | 16 L |
| Heater | 1,400 W |
| Listed temperature | 126°C |
| Power variants | 115 or 240 V |
GEMMY 2026 catalogue, page 25, exact model column. Confirm voltage, cycle validation and load suitability before procurement; a temperature rating alone does not define a validated sterilization cycle. Checked 2026-09-29.
Manufacturer reference document (opens in a new tab)
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about GEMMY Industrial equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
A bench top steam steriliser with a 230 mm diameter by 390 mm deep chamber in 304 stainless steel, approximately 16 litres, in an overall cabinet of 501 x 406 x 537 mm. Design temperature is 140 degrees C and the published working range for unwrapped, wrapped and liquid loads is 115 to 134 degrees C at 0.9 to 2.1 kg/cm2. GEMMY states the autoclave is manufactured in conformity with directive 93/42/EEC. Safety fittings are a safety valve, an emergency exhaust valve, a release valve, a door safety holder and a pressure control switch.
The largest trolley aspirator in the range at 640 x 395 x 825 mm, carrying two 3000 ml collection jars in glass or plastic with overflow prevention, and a storage cabinet on the back for accessories and tools. It takes either an oil rotary pump at 191 W giving 80 litres per minute and 700 mmHg, or a two cylinder oil-less pump at 270 W giving 70 litres per minute and 680 mmHg. Vacuum is regulated from zero to maximum and read on a built-in gauge covering 0 to 760 mmHg, with a left to right knob switching which bottle draws. Four anti-static rubber castors with two locks carry the unit, and GEMMY notes low noise operation suited to wards and theatres.
A Class B table top steriliser with a 40 litre chamber measuring 300 mm diameter by 570 mm deep, running at 121 or 135 degrees C with an automatic fill water system and a vacuum assisted drying stage selectable at 0, 15, 30, 35 or 40 minutes. Programmes cover wrapped and unwrapped loads, dry and undried, liquids, a PRION programme, Bowie-Dick and a pump test, with temperature shown digitally, pressure on a pressure and vacuum gauge and programme status on LED. It draws 3000 W at 14 A, split between a 2300 W heater, a 600 W dry heater and a 100 W vacuum pump, from a 230 V 50/60 Hz supply. Safety cover includes a 2.5 kg/cm2 pressure safety valve, independent over temperature protection, two 30 A no fuse breakers, an over pressure switch, a door lock micro-switch, water level sensors in both the tank and the chamber, and a silicone bellows pressure door lock.