Brand: Microtrac MRB | Category: Scientific & Laboratory Equipment

Laser diffraction analyser configured for airborne particles and droplets, measuring sprays, mists and atomised liquids in flight. Three interchangeable lenses cover 0.5 µm to 2000 µm, and spray measurements can be as short as 0.02 milliseconds to capture a single pulse.
| Parameter | Value |
|---|---|
| Measuring range | F100 lens: 0.5 to 350 µm ; F300lens: 1.4 to 1000 µm ; F600 lens: 2.8 to 2000 µm |
| Detector | 32-element ring detector (with automatic optical axis adjustment function |
| Measuring time | Spray measurement: 0.02 to 500 msec ; Continous measurement: 1 to 600 sec |
| Number of measurements | Spray measurement: 1 to 100 times ; Continous measurement: 1 to 9,999 times |
| Sample Cell | Material: Tempax glass (with coating) ; Capacity: 5 to 7 ml |
| Power requirements | 85 to 264 VAC, 47 to 63 hz |
| Dimensions (W x H x D) | Light emission module: 170 × 230 × 240 mm ; Detection module: 595 × 230 × 240 mm ; For connected modules (option): 1000 × 230 × 340 mm, 27 kg |
| Weight | Light emission module: 5.5 kg ; Detection module: 11.5 kg (with F300 lens attached) ; For connected modules (option): 27 kg |
Selected values from the manufacturer’s technical data for this product or explicitly named model variants. Measurement performance depends on the sample and configuration. Confirm the current model, utilities, accessories and acceptance criteria in the quotation. Checked 2026-09-29.
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Microtrac MRB equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Dynamic light scattering analyser using an external probe rather than a cuvette, so measurements can be taken in situ in a reaction vessel or process line. It covers 0.3 nm to 10 µm and works at sample concentrations up to 40 per cent, which removes the dilution step that normally distorts a DLS result.
Analyser that runs laser diffraction and dynamic image analysis on the same sample stream at the same time, so size distribution and shape data come from one measurement rather than two instruments. It covers 0.01 to 4000 µm and works to ISO 13320 and ISO 13322-2 together.
Dynamic light scattering analyser that measures particle size, zeta potential, concentration and molecular weight in one benchtop instrument. Combining size and charge in a single measurement is useful for colloid and formulation work, where stability depends on both together.