Brand: Microtrac MRB | Category: Scientific & Laboratory Equipment

Analyser that runs laser diffraction and dynamic image analysis on the same sample stream at the same time, so size distribution and shape data come from one measurement rather than two instruments. It covers 0.01 to 4000 µm and works to ISO 13320 and ISO 13322-2 together.
| Parameter | Value |
|---|---|
| Measuring range | SYNC GO: 0.1 - 2000 µm ; SYNC PLUS: 0.02 - 4000 µm ; SYNC PRO: 0.01 - 4000 µm |
| Laser power | Red laser 0.35 to 2 mW nominal ; Blue laser 4-8 mW nominal |
| Detection system | Two fixed photoelectric detectors with logarithmically spaced segments are placed at correct angles for optimal scattered light detection from 0 to 165 degrees using 151 detector segments. |
| Measuring time | ~ 10 to 30 seconds |
| Power requirements | AC input: 90 - 264 VAC, 47 - 63 Hz, single phase |
| Power consumption | 25 W nominal, 50 W max., depending on options installed |
| Dimensions (W x H x D) | ~ 820 x 460 x 500 mm (32.3 x 18.1 x 19.7 in) |
| Weight (Measuring unit) | FLOWSYNC: 19.5kg (43lbs) ; TURBOSYNC: 13.6kg (30lbs) ; SYNC: 23.6kg (50.8lbs) |
Selected values from the manufacturer’s technical data for this product or explicitly named model variants. Measurement performance depends on the sample and configuration. Confirm the current model, utilities, accessories and acceptance criteria in the quotation. Checked 2026-09-29.
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Microtrac MRB equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Laser diffraction analyser configured for airborne particles and droplets, measuring sprays, mists and atomised liquids in flight. Three interchangeable lenses cover 0.5 µm to 2000 µm, and spray measurements can be as short as 0.02 milliseconds to capture a single pulse.
Laser diffraction analyser that adds two blue 405 nm lasers to the red source, because the shorter wavelength improves resolution at the fine end. It measures from 0.01 µm to 2.8 mm and applies Mie theory for spherical particles with a modified Mie calculation for non-spherical ones.
Dynamic light scattering analyser using an external probe rather than a cuvette, so measurements can be taken in situ in a reaction vessel or process line. It covers 0.3 nm to 10 µm and works at sample concentrations up to 40 per cent, which removes the dilution step that normally distorts a DLS result.