Brand: MiE GmbH | Category: Nuclear Medicine & Imaging

This set is made up of a body phantom, a lung insert and an insert carrying six spheres of various sizes. Its design follows the recommendations of the International Electrotechnical Commission (IEC) as modified by the National Electrical Manufacturers Association (NEMA), and MiE recommend it for evaluating reconstructed image quality in whole body PET imaging. Listed applications include simulation of whole body imaging with PET and camera based coincidence techniques, determination of coincidence count rate characteristics in brain and cardiac imaging, evaluation of the relationship between true coincidence count rate and radioactivity, determination of address errors caused by address pile up, evaluation of the count loss correction scheme and research. MiE also supply customised phantoms on request.
| Parameter | Value |
|---|---|
| Phantom internal length | 180 mm |
| Fillable spheres | 6 |
| Sphere internal diameters | 10, 13, 17, 22, 28 and 37 mm |
| Sphere-plane distance to inner wall | 70 mm |
Selected configuration details published by MiE. Confirm the current supplied model, accessories and application-specific acceptance criteria. Shielding and source-related items require a design suitable for the proposed radionuclide and workload. Checked 2026-09-29.
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about MiE GmbH equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Nuclear Medicine & Imaging
MiE publish the four quadrant bar phantom in three formats. The Rectangular Bar Phantom measures 22 1/4 in x 17 in with bar sizes of 2 mm, 2.5 mm, 3 mm and 3.5 mm. The Square Bar Phantom is 16 7/8 in square with bar sizes of 1/8 in, 5/32 in, 1/4 in and 3/16 in. The Circular Bar Phantom is 16 in round with bar sizes of 2 mm, 2.5 mm, 3 mm and 3.5 mm.
An anthropomorphic PMMA body phantom for PET and PET/CT image quality testing. Six hollow fillable spheres screw into a plate on one face and can be filled with water for cold lesion imaging or with 18F FDG for hot lesion imaging.
MiE describe these as the highest quality sources for performing quality control on gamma camera systems. Every C-Thru flood source uses proprietary cobalt chemistry in the manufacturing process and is delivered with a homogeneous field of view distribution showing a coefficient of less than 1 % variation. Recommended working life of a Co-57 flood source is 2 years, and disposal of sources is arranged on request.