Brand: Microtrac MRB | Category: Scientific & Laboratory Equipment

Mercury intrusion porosimeter that forces mercury into a porous solid under increasing pressure to derive pore size distribution and total pore volume. It covers the macropore and mesopore range that gas adsorption cannot reach, and is used on ceramics, catalysts, cements and rock.
| Parameter | Value |
|---|---|
| Pressure range | LP: Vacuum up to 450 KPa ; MP: 0.1 - 228 MPa ; HP: 0.1 - 414 MPa |
| Resolution LP | 0.001 kPa in measuring range: vacuum to 0.1 kPA / 0.01 kPa in measuring range 0.1 - 450 kPA |
| Resolution MP | 0.001 MPa in measuring range 0.1 - 100 MPa / 0.01 MPa in measuring range 100 - 228 MPa |
| Resolution HP | 0.001 MPa in measuring range 0.1 - 100 MPa / 0.01 MPa in measuring range 100 - 414 MPa |
| Pressure detection accuracy | better than 0.1% F.S. |
| Pore size diameter | LP: 180 - 3.25 µm (UMP: 1,000 - 3.8 µm) ; MP: 15 - 0.0065 µm ; HP: 15 - 0.0036 µm |
| Particle size diameter | LP: 330 - 15 µm (UMP: 3,000 - 15 µm) ; MP: 40 - 0.015 µm ; HP: 40 - 0.01 µm |
| Max. detectable volume | LP & MP: 0.5 cm³ - 2 cm³ ; HP: 0.5 cm³ |
| Volume detection accuracy | better than 1% F.S. |
| Max. number of measuring points | 10.000 intrusion ; 10.000 extrusion |
Selected values from the manufacturer’s technical data for this product or explicitly named model variants. Measurement performance depends on the sample and configuration. Confirm the current model, utilities, accessories and acceptance criteria in the quotation. Checked 2026-09-29.
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Microtrac MRB equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Gas pycnometer that determines true density of powders and porous solids by measuring the volume of gas that the sample displaces, so open pores are excluded from the volume. Helium is normally used because its small molecule penetrates fine pore structures.
High pressure adsorption instrument for measuring gas uptake well above atmospheric pressure. That is the regime that matters for hydrogen and methane storage, for carbon dioxide capture and for screening adsorbents used in gas separation. Isotherms are measured volumetrically, as on the other BELSORP instruments, but with a pressure range that ordinary surface area analysers do not reach.
Larger chamber version of the BELPYCNO gas pycnometer, for samples too bulky for the standard cell. It uses the same gas displacement principle to give true density excluding open porosity.