Brand: Microtrac MRB | Category: Scientific & Laboratory Equipment

High pressure adsorption instrument for measuring gas uptake well above atmospheric pressure. That is the regime that matters for hydrogen and methane storage, for carbon dioxide capture and for screening adsorbents used in gas separation. Isotherms are measured volumetrically, as on the other BELSORP instruments, but with a pressure range that ordinary surface area analysers do not reach.
| Parameter | Value |
|---|---|
| Pressure transducer | Ads isotherm measurements can be achieved by F.S 0.133 MPa and F.S. 13.5 MPa pressure transducers from low to high pressure region. |
| Measurement pressure range | 90% of high pressure transducer F.S. |
| Temperature range | Measurement temp: ; Water bath + Chiller:-10-70°C (non-freezing liquid for settings below 10°C) ; Dewar vessel with LN 2 or LAr level controller: 77K, 87K (OP) ; Pretreatment temp: ; 50-400°C (OP:50-800°C) |
| Dimensions (W x H x D) | 600 x 910 x 720 mm |
| Weight | 90 kg |
| Utility - Power | AC 100 ~ 120V/200 ~ 240 V, 800 W (excluding vacuum pump) , 50 / 60 Hz |
Selected values from the manufacturer’s technical data for this product or explicitly named model variants. Measurement performance depends on the sample and configuration. Confirm the current model, utilities, accessories and acceptance criteria in the quotation. Checked 2026-09-29.
Share the details you know so we can prepare a comparable, itemised offer.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Microtrac MRB equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Mercury intrusion porosimeter that forces mercury into a porous solid under increasing pressure to derive pore size distribution and total pore volume. It covers the macropore and mesopore range that gas adsorption cannot reach, and is used on ceramics, catalysts, cements and rock.
Cryogenic temperature control unit for BELSORP adsorption analysers, replacing the liquid nitrogen dewar with a closed cycle cooler. It removes the need to refill coolant during long isotherm runs and holds the adsorption temperature more steadily than an evaporating bath.
Gas pycnometer that determines true density of powders and porous solids by measuring the volume of gas that the sample displaces, so open pores are excluded from the volume. Helium is normally used because its small molecule penetrates fine pore structures.